CHF 96.60
CHF 96.60
excl. VAT
Available: 1.0 Units
This combination does not exist.
Units of Measure: Units
Add to basket
Thread: M12x1
Product information:
Switching pressure 1-10 (+-0.5bar)
T4040, T4050 DELUXE AND SUPERSTEER
TN60A, TN70A, TN75A, TN85A, TN95A
TN60DA, TN70DA, TN75DA, TN85DA, TN95DA
TN60SA, TN70SA, TN75SA, TN85SA
ONLY IF EQUIPPED WITH POWERSHUTTLE TRANSMISSION
CONCERNS: DEFECTIVE LOW PRESSURE SWITCH OF THE
POWERSHUTTLE TRANSMISSION
DESCRIPTION:
To improve durability and reliability, the low pressure switch of the Powershuttle transmission has been
of the Powershuttle transmission has been modified.
The 11-bar switch has been replaced by a 10-bar switch which, together with a choke
(87745448).
The choke prevents pressure peaks in the system caused by operation of the dump valve and their effects.
pressure peaks in the system and their effects on internal components of the switch.
PRODUCTION:
The new 10-bar pressure switch (87494633) and choke (87745448) were introduced into production from the following serial numbers
the following serial numbers:
T4000 series: Z8JA04591
TNA, TNDA and TNSA series: HJE115907
The new choke has a 1 mm opening.
Note: The 10-bar pressure switch with part number 87494633 is currently in other
other product lines and applications.
For machines before the affected serial numbers:
Should a defect occur in the low pressure switch of the Powershuttle gearbox, it is recommended,
the 10-bar pressure switch, part number 87494633, and the new choke, part number 87745448.
part number 87745448. This will also require two seal rings 10280060.
PARTS AFFECTED:
The pressure switch 87494633 replaces EXCLUSIVELY the pressure switch 87395493 /5157750 as the
pressure switch for the low pressure of the Powershuttle gearbox.
The pressure switch 87395493 remains available as a spare part for all other uses and product series.
product series.
Checkout